Fluid Pump, A/T
CLEARANCESOuter Race
To-Crescent Dam [a]
Standard clearance 0.14-0.21 mm (0.006-0.008 inch)
Maximum 0.25 mm (0.010 inch)
To-Housing
Standard 0.05-0.20 mm (0.002-0.008 inch)
Maximum 0.25 mm (0.010 inch)
Side Clearance
Standard 0.02-0.04 mm (0.001-0.002 inch)
Maximum 0.08 mm (0.003 inch)
Seal Ring To Groove (All Four)
Standard 0.04-0.16 mm (0.002-0.006 inch)
Maximum 0.40 mm (0.016 inch)
Pump Housing Bushing
Sleeve Outer Diameter, Min. 37.900mm (1.492 inches)
Cover Bushing Inside Diameter, Max. 38.075mm (1.499 inches)
Cover to Housing
Below Surface, Max. 0.10 mm (0.004 inch)
Above Surface, Max. 0.15 mm (0.006 inch)
TIGHTENING SPECIFICATIONS
Cover Bolts 11-14 Nm (95-122 inch lbs.)
Mounting Bolts 15-22 Nm (11-16 ft. lbs.)
[a] Measure the clearance between the edge of the outer gear teeth and the crescent dam. Take this measurement at the high point of the crescent, with the outer gear pressed against the pump housing.