Blower Motor Relay: Testing and Inspection
1. Remove the relay from the dash fuse box.
2. Refer to image for terminal identification and circuit diagram, and test as follows:
- There should be continuity between the A and B terminals when battery power and ground are connected to the C and D terminals.
- There should be no continuity when the battery is disconnected.